Read-only example

This page shows what a completed TenderCheck review looks like. All content is illustrative sample data — no real project, client or customer documents are shown, and nothing on this page can be edited.

Tender / DEMO-001

Riverside Health Centre — M&E Installation

Example NHS Trust (illustrative) · Manchester · Healthcare

INITIAL REVIEW COMPLETERisk HIGHReturn 12 SEP 2026 / 12:00
Documents
6
Findings
7
Open conflicts
1
Updated reqs
1
Clarifications
3
Submission items
5
01 / Structured Findings

Every finding tied to its source

The initial review runs automatically across the indexed documents and returns categorised requirements and risks — not a chat transcript.

COMMERCIAL
2 findings
HIGHCONFIRMEDLiquidated DamagesConfidence HIGH

Liquidated damages set at £8,500 per week

Delay damages are levied at £8,500 per week or part week, capped at 10% of the contract sum.

Value: £8,500 / week, capped at 10%

Suggested action: Check the cap against your programme risk allowance before pricing.

SourceExample — Preliminaries.pdfClause 2.32Page 18

Liquidated damages shall be payable at the rate of £8,500 per week or part thereof, subject to an aggregate cap of 10% of the Contract Sum.

MEDIUMCONFIRMEDPaymentConfidence HIGH

Retention of 5% reducing to 2.5% at practical completion

Retention is held at 5% during the works, halved at practical completion and released after 12 months.

Value: 5% / 2.5% / 12 months

Suggested action: Confirm the cash-flow impact of the 12 month release period.

SourceExample — Contract Particulars.pdfPayment TermsPage 6

Retention: 5% of the value of work properly executed, reducing to 2.5% upon Practical Completion.

DESIGN
1 findings
HIGHCONFIRMEDDesign ResponsibilityConfidence HIGH

Contractor's design portion covers mechanical and electrical services

Full CDP responsibility for M&E design development, including coordination and BIM to LOD 400.

Value: CDP — M&E services, LOD 400

Suggested action: Allow design fees and confirm PI insurance meets the required limit.

SourceExample — Employer's Requirements.pdfSection 3.1Page 11

The Contractor shall complete the design of the Mechanical and Electrical Services in accordance with the Employer's Requirements and deliver federated models to LOD 400.

PROGRAMME
2 findings
MEDIUMSUPERSEDEDKey DatesConfidence HIGH

Tender return date moved to 12 September 2026

Addendum 01 extends the tender return date. The earlier date in the Invitation to Tender no longer applies.

Value: 12 Sep 2026 (was 29 Aug 2026)

Suggested action: Plan the submission against the amended return date.

SourceExample — Addendum 01.pdfItem 1Page 1

The Tender Return Date is changed from 29 August 2026 to 12 September 2026. All other requirements remain unchanged.

HIGHCONFIRMEDSectional CompletionConfidence MEDIUM

Ward block handover required six weeks early

The ward block must be handed over six weeks ahead of overall completion, with commissioning complete.

Value: Sectional completion — Section A

Suggested action: Price additional resource for the early sectional handover and witness testing.

SourceExample — Employer's Requirements.pdfProgramme ConstraintsPage 24

Section A (Ward Block) shall achieve Sectional Completion no later than six (6) weeks prior to the Date for Completion.

TECHNICAL
1 findings
MEDIUMCONFIRMEDStandardsConfidence HIGH

Healthcare ventilation must comply with HTM 03-01

Ventilation to clinical areas must be designed, installed and validated to HTM 03-01 Part A with independent validation.

Value: HTM 03-01 Part A

Suggested action: Include independent validation and specialist commissioning in the price.

SourceExample — M&E Specification.pdfVentilationPage 42

All ventilation systems serving clinical areas shall comply with HTM 03-01 Part A and be validated by an independent Authorised Person (Ventilation).

SUBMISSION
1 findings
HIGHCONFIRMEDTender ReturnConfidence HIGH

Tender return via procurement portal only, 12:00 noon

Submissions are accepted only through the procurement portal; late or emailed returns are rejected.

Value: Portal, 12:00 noon

Suggested action: Upload the return the working day before the deadline.

SourceExample — Invitation to Tender.pdfReturn InstructionsPage 3

Tenders must be uploaded to the Portal by 12:00 noon. Tenders received by any other means will not be considered.

02 / Cross-document Conflicts

Contradictions between documents are surfaced, not averaged away

TenderCheck compares current requirements across the whole document set. Explicit addendum changes are marked SUPERSEDED; genuine disagreements are raised as conflicts.

Conflict / TC-X-001
HIGH priority
RESPONSIBILITY_CONFLICTStandby generator supply responsibility

Two current documents allocate the standby generator to different parties. Neither is superseded, so the allocation is unresolved.

Allocated to Contractor

The Contractor shall supply, install and commission the standby generator set.

Example — M&E Specification.pdf / LV Distribution / Page 57

Allocated to Employer

The standby generator will be free-issued by the Employer for installation by others.

Example — Scope of Works.pdf / Section 9.2 / Page 31

Required action: Raise a clarification before pricing. Do not assume either allocation.

Superseded by Addendum 01
Updated

The tender return date changed from 29 Aug 2026 to 12 Sep 2026. This is a revision, not a conflict, so it is applied as the current requirement instead of being raised for clarification.

SourceExample — Addendum 01.pdfItem 1Page 1

The Tender Return Date is changed from 29 August 2026 to 12 September 2026.

03 / Document Register

Every document indexed and tracked

DocumentTypePagesStatus
Example — Invitation to Tender.pdfITT12INDEXED
Example — Employer's Requirements.pdfER148INDEXED
Example — M&E Specification.pdfSPECIFICATION214INDEXED
Example — Preliminaries.pdfPRELIMINARIES36INDEXED
Example — Contract Particulars.pdfCONTRACT22INDEXED
Example — Addendum 01.pdfADDENDUM3INDEXED
04 / Submission Requirements

What must be returned, extracted automatically

Submission Checklist
5 outstanding
  • Priced schedule of works (Excel)

    Fully priced, no blank lines, in the issued format.

    Outstanding
  • Tender programme (Gantt)

    Showing sectional completion for the ward block.

    Outstanding
  • Method statement — M&E installation

    Maximum 10 pages including coordination approach.

    Outstanding
  • Proposed sub-contractor list

    With collateral warranty confirmation for each.

    Outstanding
  • Company health & safety policy

    Signed and dated within the last 12 months.

    Outstanding
05 / Suggested Clarifications

Drafted from the gaps found in the documents

TC-C-001
Draft

Standby generator responsibility

The specification and the scope of works conflict on who supplies the standby generator.

Please confirm whether the standby generator is contractor-supplied or free-issued by the Employer.

Example — M&E Specification.pdf / LV Distribution / Page 57

TC-C-002
Draft

Sectional completion scope boundary

The ward block boundary is not defined on the tender drawings.

Please confirm the physical extent of Section A (Ward Block) for the purposes of sectional completion.

Example — Employer's Requirements.pdf / Programme Constraints / Page 24

TC-C-003
Draft

Warranty liability period

A 12 year liability period exceeds terms typically accepted by specialist suppliers.

Would the Employer accept a 6 year liability period for sub-contractor warranties?

Example — Contract Particulars.pdf / Third Party Rights / Page 9

06 / Ask Tender

Answers checked across the whole document set

Ask / Example
CONFIRMED
Question

Who is responsible for fire stopping around mechanical penetrations?

Answer

The Mechanical Contractor is responsible for fire stopping to penetrations formed for mechanical services, and must provide certification for each penetration on completion.

Cross-checked against 6 indexed documents. No contradictory allocation found in current (non-superseded) requirements.

2 sources
SourceExample — M&E Specification.pdfSection 7.4.2Page 137

Fire stopping to all penetrations formed by the Mechanical Contractor shall be carried out by the Mechanical Contractor using an approved third-party certified system.

SourceExample — Scope of Works.pdfSection 12.8Page 24

Each services contractor shall make good and fire stop penetrations formed for its own services.

Early Access

Run this on your own tender

Upload your tender documents and TenderCheck produces the same structured review, with every finding referenced back to the source page.

TenderCheck provides AI-assisted document analysis. Findings may be incomplete or inaccurate and should be verified against original tender documentation by appropriately qualified personnel. TenderCheck does not provide legal, contractual, engineering or commercial advice.